US & CANADA
1-888-667-3421
WORLDWIDE
1-514-881-8136

KD NaK filled Melt pressure transmitters

 
Please Indicate your product number here or select from the options on the right:
 
 
Available Configuration:
OptionsCodeDescription
OUTPUT SIGNALCAN BUS
VERSION0Rigid stem
CONNECTOR55 pin M12
ACCURACY CLASSH0.25% FSO (ranges ≥ 100 bar/1500 psi)
RANGEB35Ubar - 35
THREAD11/2 - 20 UNF
RIGID STEM LENGTH (mm / inches) (*)4Standard (KD0, KD1, KD2) - 153mm - 6"
FLEXIBLE STEM LENGTH (mm / inches) (*)0Standard (KD0) - none
CONTACT DIAPHRAGMIINCONEL 718 (538°C*)
Standard version000Standard version
OUTPUT SIGNAL
VERSION
CONNECTOR
ACCURACY CLASS
RANGE
THREAD
RIGID STEM LENGTH (mm / inches) (*)
(*) max combined rigid/flexible stem length is 1000mm - 39”
FLEXIBLE STEM LENGTH (mm / inches) (*)
(*) max combined rigid/flexible stem length is 1000mm - 39”
CONTACT DIAPHRAGM
* max temperature
Standard version
000= Standard version
Special or customized versions
available on request

Application:
  • As for FDA approval,  K series is suitable for Mercury free , food and medical application
  • Processing  special polymers, technopolymers (538°C /1000°F)
    Electrical
  • Digital output signal with DP404 CAN OPEN communication protocol
  • Transmission frequency (Baud rate): 10 Kbaud to 1 Mbaud (default 500 Kbaud)
  • Software / Hardware selection of Baud rate and ID nodes
  • Operation with 1 or 2 settable alarm limits
  • “Autozero” for temperature compensation
  • Zero and span drift compensation
  • 80% FSO calibration signal

    Mechanical
  • Pressure ranges: 0-35 to 0-700 bar / 0-500 to 0-10000 psi
  • Accuracy: < ± 0.25% FSO (H); < ±0.5% FSO (M)
  • Hydraulic transmission system to guarantee temperature stability (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS).
  • Quantity of NaK contained per model: KD0 series (30mm3) (0.00183 in3), KD1,KD2,KD3 series (40mm3) (0.00244 in3)
  • Standard threading: 1/2-20 UNF, M18x1.5; other versions on request.
  • Inconel 718 diaphragm with GTP coating for temperatures up to 538°C (1000°F)
  • 15-5 PH diaphragm with GTP coating for temperatures up to 400°C (750°F)
  • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F).
  • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100 bar-1500 psi